K тип NiCrNi Ф1х0100mm+3m кабел термодвойка мантелна 1100 ºC ЗАЗЕМЕНА Maximize

K type NiCrNi d1x0100mm + 3m cable thermocouple GROUNDED

Application: In the case that requires the use of a miniature thermocouple and / or fast acting, high temperature resistance of the order of 800 °C, using this type of structure, Thermocouples default are insulated from the housing. Grounded thermocouples are fast-acting, but grounding them may make inadmissible galvanic connection with some controllers.

More details

TCMI-K1x100Gss316+3m

3 Items in stock

78,00 лв

K type NiCrNi d1x0100mm + 3m cable thermocouple mantle GROUNDED
RANGE [oC]: 0 ... 800  
CONSTRUCTION thermocouple active part:
(MI) -Mineral insulated with compacted Magnesium Oxide (MgO) wires encased in a protective sheath resistant mantle,
Type of conductors: K (NiCr-Ni)
Diameter of the wires d [mm]: 0.15 ... 0.20
Material of the outer shell: SS316
Diameter outer, d [mm]: 1
Length, L [mm]: 100
TC heated end: with welded casing
CONSTRUCTION CABLE:
Thermal resistance [° C]: 400
Type: extension, KX
Code: KX-FG-FG-SSB-2x7x0.2mm
Length, k [m]: 3
Cables, No: 2
Conductor, section [mm2]: 0,22
Number of wires in conductor: 7
Diameter of each wire [mm]: 0,2
Conductor, insulation, glass braid
Common shell: glass braid
Shield, protecting, braided stainless steel
Color code: IEC: green / (-) white (+) green
CONNECTION MI with cable: molded and crimping tube
Tube, approx. size d[mm]: 8x31
Accessory: Shielding spring against breaking cable
 
 

 

  • Type temperature sensor Thermocouple K
  • Operating temperature 0÷1100 °C
  • Type of protective head: Version with cable
  • Diameter sensor: ф1 mm
  • Length of the sensor: 100 mm

Write your review

K type NiCrNi d1x0100mm + 3m cable thermocouple GROUNDED

K type NiCrNi d1x0100mm + 3m cable thermocouple GROUNDED

Application: In the case that requires the use of a miniature thermocouple and / or fast acting, high temperature resistance of the order of 800 °C, using this type of structure, Thermocouples default are insulated from the housing. Grounded thermocouples are fast-acting, but grounding them may make inadmissible galvanic connection with some controllers.

Write your review