SPECIFICATIONS
  Power supply:  10-32VDC
  Output:  4~20mA DC
  Stability:
0.01°C(RTD), 0.1°C(E J K N T), 0.2°C(B R S)
  Accuracy:
0.1°C(RTD), 0.5°C(E J K N T), 1.0°C(B R S)
  Operating temperature:  -40°C ~ +85°C
  Dimension:
DiameterΦ= 44 mm,
Mounting hole pitch D = 33 mm
Weight: 35 g
Features:
1,  High reliability and exceptional EMC performance: Built-in multi-level protection circuit for high reliability.
 2, High-voltage isolation:  As high as 1000V for the isolation voltage between metal capacitance sensor processing circuit and main circuit.
 3,  HVRT communication protocol: PC programmable
 4,  High performance-price ratio: HVRT digital bus communication, low price, high precision, good quality.
 5,  Easy to install and reliable with unique design.
 6, HVRT protocol is a proprietary communication protocol developed by our company, based on the voltage    modulation. Similar as HART communication protocol.  
 
Signal Type
Measurements Range
Minimum
Range
Output Accuracy
 
Thermocouples
(TC)
T
-200~400 °C
25 °C
±0.4 °C /0.2%
E
-200~1000 °C
25 °C
±0.4 °C /0.2%
J
- 210~1200 °C
25 °C
±0.4 °C /0.2%
K
-200~1372 °C
25 °C
±0.4 °C /0.2%
N
-200~1300 °C
25 °C
±0.4 °C /0.2%
R
0~1768 °C
100 °C
±0.8 °C /0.2%
S
0~1768 °C
100 °C
±0.8 °C /0.2%
B
150~1820 °C
100 °C
±1.0 °C /0.2%
mV input
-120~120mV
10mV
±10μV /0.2%
-1000~1000mV
50mV
±100μV /0.2%
Resistance
Temperature
(RTD)
Pt50
-200~850 °C
10 °C
±0.15 °C /0.2%
Pt100
-200~850 °C
10 °C
±0.15 °C /0.2%
Pt500
-200~850 °C
10 °C
±0.1 °C /0.2%
Pt1000
-200~850 °C
10 °C
±0.1 °C /0.2%
Ohm input
0~500  Ω
100Ω
±0.2 Ω/0.2%
0~4500  Ω
100Ω
±1.0 Ω/0.2% 
 
 
 
 
 
 
 
 
 Optional:
We offer HVRT communicator and program;
We reprogramming of already put into operation, transmitters.

 

 

 