Level control FILLING pump 2 working and 2 alarm levels
Level controller VCL2 control the presence of four levels of conductive principle and controlled by an external pump output relay (solenoid valve) by which FILLING the tank and through the output relays implemented lock and alarm. This performance is in a secure box with IP55 level and is intended for mounting on a wall near the tank.
Operating method is based on use of electrodes, that make contact when are covered withElectroconductive liquid. The simplicity of measurement method determine the low price at high reliability for these type of level probes.Power supply: 220 V AC, option 24VACPower supply on probes: 15 V ACPower consumption: Max. 3 VAOutputs: 3 switching contactsSensibility control: by potentiometerOutputs electrical characteristics: 4 A, 250 V ACIndication for output relay condition: LEDController dimensions:- version with IP 55: 160 x 120 x 80 mmOperating conditions for controller:- temperature: ( 0 ... +50 )°C- relative humidity: up to 80%Controller mounting:- version with IP 55 - screw on wallProtection system of controller: IP 55Technical drawing:
Rated current: 4A
Rated voltage: 230 VAC
Controllers control law: Positional (on-off)
Контролери видове изходи alarm relay output SPDT or SPST